Question 1. A technician measures a refrigerant saturation temperature of 40°F at the evaporator outlet. The suction-line temperature at the same location is 57°F. What is the measured superheat?
A. 12°F
B. 17°F
C. 20°F
D. 97°F
Correct Answer: B. 17°F
Answer Explanation:
Option B is correct because superheat is calculated by subtracting the saturation temperature from the actual refrigerant vapor temperature. The calculation is 57°F − 40°F = 17°F. Superheat helps determine whether refrigerant leaving the evaporator has been heated above its saturation temperature. Technicians use this measurement to assess evaporator feeding and system operation, but the acceptable value depends on the metering device, equipment specifications, and operating conditions. Superheat alone cannot establish whether the refrigerant charge is correct. Other measurements, including suction pressure, airflow, and system load, should be considered before making adjustments.
Why the other options are incorrect:
Option A is incorrect because the stated temperatures differ by 17°F, not 12°F.
Option C is incorrect because 20°F does not match the calculated temperature difference.
Option D is incorrect because adding the two temperatures does not calculate superheat.
Quick Study Guide:
Superheat = actual suction-line temperature − saturation temperature.
Use the correct refrigerant pressure-temperature relationship.
Compare readings with the manufacturer’s specifications.
Evaluate operating conditions before adjusting refrigerant charge.
Question 2. An air-conditioning compressor repeatedly trips its overload protector. The condenser coil is clean, the condenser fan is operating, and the supply voltage is within the manufacturer’s specified range. Which diagnostic step is most appropriate?
A. Increase the circuit-breaker rating.
B. Add refrigerant without taking further measurements.
C. Bypass the overload protector to keep the compressor running.
D. Measure compressor current and operating pressures, then compare the results with manufacturer specifications.
Correct Answer: D. Measure compressor current and operating pressures, then compare the results with manufacturer specifications.
Answer Explanation:
Option D is correct because repeated overload trips can result from excessive current, abnormal operating pressures, electrical faults, or internal compressor problems. A clean condenser and functioning fan eliminate some possible causes but do not establish the actual fault. Measuring current and refrigeration pressures provides evidence that can help narrow the diagnosis. The technician should also evaluate operating conditions and other electrical measurements as appropriate. Replacing parts or adding refrigerant without supporting evidence may introduce additional problems. The overload protector must remain functional throughout the diagnostic process because it helps prevent damage from unsafe operating conditions.
Why the other options are incorrect:
Option A is incorrect because increasing breaker capacity without verifying circuit requirements can create an electrical hazard.
Option B is incorrect because an undercharge has not been established.
Option C is incorrect because bypassing overload protection can damage the compressor and create unsafe conditions.
Quick Study Guide:
Compressor overload trips have multiple possible causes.
Compare current and pressure readings with equipment specifications.
Verify electrical and refrigeration conditions before selecting a repair.
Never bypass compressor safety protection.
Question 3. A commercial building has uneven cooling between rooms. The air handler operates normally, but measurements show high external static pressure and low airflow. Inspection reveals several closed supply dampers and a restricted duct section. What should the technician do first?
A. Correct the airflow restrictions and verify system performance afterward.
B. Increase refrigerant charge to compensate for the reduced airflow.
C. Replace the thermostat with one that has a lower temperature setting.
D. Reduce return-air opening size to increase supply pressure.
Correct Answer: A. Correct the airflow restrictions and verify system performance afterward.
Answer Explanation:
Option A is correct because closed dampers and restricted ductwork increase resistance to airflow. This can raise external static pressure and reduce the air delivered to occupied spaces. Reduced airflow can also affect evaporator heat transfer and overall cooling capacity. The technician should inspect the duct system, correct the restrictions, and check damper positions according to the design requirements. After the corrections, airflow and static pressure should be measured again to confirm improvement. Adjusting refrigerant charge or changing thermostat settings will not resolve the underlying distribution problem. Accurate diagnosis begins with addressing the documented restriction rather than changing unrelated system components.
Why the other options are incorrect:
Option B is incorrect because refrigerant charge does not correct restricted ductwork.
Option C is incorrect because a lower thermostat setting does not restore adequate airflow.
Option D is incorrect because restricting return air can further reduce system airflow.
Quick Study Guide:
High static pressure can indicate excessive airflow resistance.
Inspect ducts, dampers, and return-air pathways.
Correct restrictions before evaluating refrigeration performance.
Verify airflow after repairs.
Question 4. A contractor is installing an outdoor condensing unit near a wall and beneath a roof overhang. The proposed location does not meet the manufacturer’s required airflow clearances. What is the appropriate action?
A. Install the unit because the condenser fan will overcome the restriction.
B. Increase the refrigerant charge to compensate for restricted heat rejection.
C. Revise the installation location to maintain the manufacturer’s specified clearances.
D. Reduce the required clearance to fit the available space.
Correct Answer: C. Revise the installation location to maintain the manufacturer’s specified clearances.
Answer Explanation:
Option C is correct because an outdoor condenser needs sufficient clearance to reject heat effectively. An obstruction above or around the unit can restrict airflow or cause hot discharge air to recirculate into the coil. This may increase condensing pressure, raise compressor workload, and reduce system performance. The contractor should select a location that meets the manufacturer’s installation instructions and applicable requirements. If the proposed space cannot provide the necessary clearance, the layout should be changed before installation proceeds. Correct placement supports reliable operation and helps prevent problems that may otherwise be mistaken for refrigerant or component faults.
Why the other options are incorrect:
Option A is incorrect because the fan cannot reliably overcome every installation restriction.
Option B is incorrect because additional refrigerant does not correct inadequate condenser airflow.
Option D is incorrect because ignoring specified clearances can compromise equipment performance and installation compliance.
Quick Study Guide:
Condensers require adequate airflow to reject heat.
Follow manufacturer clearance requirements.
Prevent hot discharge air from recirculating.
Correct installation problems before commissioning.
Question 5. After repairing a leaking refrigerant line, a technician must verify the circuit’s integrity before charging the system. Which procedure is most appropriate?
A. Charge the system immediately because the repaired joint appears sound.
B. Pressure-test with an approved inert gas within specified limits, repair any leaks, and evacuate the system according to manufacturer instructions.
C. Pressurize the circuit with oxygen to identify leaks.
D. Use compressed air above the component pressure rating to expose small leaks.
Correct Answer: B. Pressure-test with an approved inert gas within specified limits, repair any leaks, and evacuate the system according to manufacturer instructions.
Answer Explanation:
Option B is correct because repaired refrigerant piping must be tested for leaks before the system returns to service. Dry nitrogen is commonly used when permitted by the manufacturer’s procedure. The technician must use a suitable regulator and pressure-rated equipment, keeping the test pressure within the specified limits of all connected components. Any detected leaks must be repaired and the circuit retested. Once the pressure test is successful, the system should be evacuated according to manufacturer requirements to remove air and moisture before charging. Pressure testing confirms circuit integrity, while evacuation removes unwanted gases and moisture. These are separate steps and neither should be skipped.
Why the other options are incorrect:
Option A is incorrect because a repaired joint can still leak even when it appears sound.
Option C is incorrect because oxygen can react dangerously with refrigeration oil under pressure.
Option D is incorrect because compressed air introduces moisture and oxygen, while excessive pressure can damage equipment.
Quick Study Guide:
Pressure-test repaired piping before charging.
Use approved inert gas and regulated equipment.
Never exceed specified pressure limits.
Evacuate the circuit properly before charging.